Kraus & Naimer C80 A271 4-Step Cam Switch without OFF, 3-Pole, 115 A, 88 x 88 mm Front Plate
- Brand: Kraus & Naimer
- SKU: C80 A271
- MPN: C80 A271
- Model: 115 A
- Price: 16476.00 TRY + VAT · incl. VAT 19771.20 TRY
- Availability: Made to order
- Standard Step Switches
- Kraus & Naimer Standard Step Switches
- Selection guide: Standard Step Switches Selection Guide
Kraus & Naimer C80 A271 is a 3-pole, 115 A step switch with 4 steps and no OFF position. The switch has positions 1-2-3-4, a switching angle of 60° and 6 levels. Front plate size 88 x 88 mm; front plate code F077; size type S2. Rated insulation voltage is 690 V (AC 50/60 Hz) and rated impulse withstand voltage is 6 kV. AC-21A rated operational current is 100 A over 20–690 V; three-phase AC-3 rated power (380–440 V) is 30 kW; AC-23A rated power (380–440 V) is 45 kW. Maximum fuse rating gG 125 A; rated short-time withstand current 1300 A (1 s); power loss per pole 5.8 W. The terminals accept stranded conductors up to 35 mm²; tightening torque is 4 Nm (35 lb-in); operating temperature is -25…+60 °C. It is used to select between several circuit steps; there is no OFF (0) position.
| Size Type | S2 |
|---|---|
| Number of Poles | 3P |
| Cam Switch Position Count | 4 Positions |
| Series | C80 |
| Function Code | A271 |
| Switch Function | Stepped Without Off (1-2-3-4) |
| Switch Positions | 1-2-3-4 |
| Number of Positions | 4 |
| Switching Angle | 60° ° |
| Number of Levels | 6 |
| Front Plate Code | F077 |
| Front Plate Size (A x B) | 88 x 88 mm |
| Rated Current | 115 A |
| Conventional Free Air Thermal Current (Ith) | 115 A |
| Ambient temperature for rated current | 55 °C (24 hours, tepe 60 °C) |
| Conventional Enclosed Thermal Current (Ithe) | 115 A |
| Rated Insulation Voltage (Ui) | 690 V (AC 50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Overvoltage category | III |
| Pollution Degree | 3 |
| Rated Operational Current AC-20A (Ie) | 690 V: 115 A |
| Rated Operational Current AC-21A (Ie) | 20–690 V: 100 A |
| Rated Operational Current AC-22A (Ie) | 220–500 V: 100 A; 660–690 V: 100 A |
| Rated Operational Power AC-2 (Pe) | 3-phase: 220–240 V 30 kW; 380–440 V 45 kW; 500 V 55 kW; 660–690 V 55 kW |
| Rated Operational Power AC-3 (Pe) | 3-phase: 220–240 V 15 kW; 380–440 V 30 kW; 500 V 30 kW; 660–690 V 30 kW. 1-phase: 110–120 V 3.7 kW; 220–240 V 7.5 kW; 380–440 V 13 kW |
| Rated Operational Power AC-4 (Pe) | 3-phase: 220–240 V 6 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 5.5 kW |
| Rated Operational Power AC-23A (Pe) | 3-phase: 220–240 V 30 kW; 380–440 V 45 kW; 500 V 55 kW; 660–690 V 45 kW. 1-phase: 110–120 V 5.5 kW; 220–240 V 15 kW; 380–440 V 22 kW |
| Maximum Fuse Current | gG 125 A |
| Rated Short-Time Withstand Current (Icw) | 1300 A (1 s) |
| Breaking Capacity | 220–240 V: 860 A; 380–440 V: 860 A; 660–690 V: 400 A |
| Power Loss per Pole | 5.8 W |
| Solid Conductor Cable Cross-Section | 2.5–35 mm2 |
| Stranded Conductor Cable Cross-Section | 35 mm2 |
| Flexible Conductor Cross-Section | 6–25 mm2 |
| Conductor Cross-Section with Ferrule | 4–25 mm2 |
| Cable section (AWG/MCM) | AWG 3 (flexible); AWG 2 (solid or stranded) |
| Conductor Material | Copper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered) |
| Tightening Torque | 4 Nm (35 lb-in) |
| Recommended Screw Driver | Pozidriv/Phillips PH2; slotted 1.2 x 8 mm (DIN 5264) |
| Contact Type | Rigid bridging link |
Shipping & assurance
For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.
In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.