Kraus & Naimer C80 A285 7-Step Cam Switch with OFF, 3-Pole, 115 A, 88 x 88 mm Front Plate

Kraus & Naimer C80 A285 7-Step Cam Switch with OFF, 3-Pole, 115 A, 88 x 88 mm Front Plate

Kraus & Naimer C80 A285 is a 3-pole, 115 A step switch with 7 steps and an OFF position. The switch has positions 0-1-2-3-4-5-6-7. Front plate size 88 x 88 mm; size type S2. Rated insulation voltage is 690 V (AC 50/60 Hz) and rated impulse withstand voltage is 6 kV. AC-21A rated operational current is 100 A over 20–690 V; three-phase AC-3 rated power (380–440 V) is 30 kW; AC-23A rated power (380–440 V) is 45 kW. Maximum fuse rating gG 125 A; rated short-time withstand current 1300 A (1 s); power loss per pole 5.8 W. The terminals accept stranded conductors up to 35 mm²; tightening torque is 4 Nm (35 lb-in); operating temperature is -25…+60 °C. It is used to select between several circuit steps; the circuit is open in the 0 position.

Size TypeS2
Number of Poles3P
Cam Switch Position Count7 Positions
SeriesC80
Function CodeA285
Switch FunctionStepped With Off (0-1-2-3-4-5-6-7)
Switch Positions0-1-2-3-4-5-6-7
Number of Positions8
Front Plate Size (A x B)88 x 88 mm
Rated Current115 A
Conventional Free Air Thermal Current (Ith)115 A
Ambient temperature for rated current55 °C (24 hours, tepe 60 °C)
Conventional Enclosed Thermal Current (Ithe)115 A
Rated Insulation Voltage (Ui)690 V (AC 50/60 Hz)
Rated Impulse Withstand Voltage (Uimp)6 kV
Overvoltage categoryIII
Pollution Degree3
Rated Operational Current AC-20A (Ie)690 V: 115 A
Rated Operational Current AC-21A (Ie)20–690 V: 100 A
Rated Operational Current AC-22A (Ie)220–500 V: 100 A; 660–690 V: 100 A
Rated Operational Power AC-2 (Pe)3-phase: 220–240 V 30 kW; 380–440 V 45 kW; 500 V 55 kW; 660–690 V 55 kW
Rated Operational Power AC-3 (Pe)3-phase: 220–240 V 15 kW; 380–440 V 30 kW; 500 V 30 kW; 660–690 V 30 kW. 1-phase: 110–120 V 3.7 kW; 220–240 V 7.5 kW; 380–440 V 13 kW
Rated Operational Power AC-4 (Pe)3-phase: 220–240 V 6 kW; 380–440 V 11 kW; 500 V 11 kW; 660–690 V 11 kW. 1-phase: 110–120 V 1.5 kW; 220–240 V 3 kW; 380–440 V 5.5 kW
Rated Operational Power AC-23A (Pe)3-phase: 220–240 V 30 kW; 380–440 V 45 kW; 500 V 55 kW; 660–690 V 45 kW. 1-phase: 110–120 V 5.5 kW; 220–240 V 15 kW; 380–440 V 22 kW
Maximum Fuse CurrentgG 125 A
Rated Short-Time Withstand Current (Icw)1300 A (1 s)
Breaking Capacity220–240 V: 860 A; 380–440 V: 860 A; 660–690 V: 400 A
Power Loss per Pole5.8 W
Solid Conductor Cable Cross-Section2.5–35 mm2
Stranded Conductor Cable Cross-Section35 mm2
Flexible Conductor Cross-Section6–25 mm2
Conductor Cross-Section with Ferrule4–25 mm2
Cable section (AWG/MCM)AWG 3 (flexible); AWG 2 (solid or stranded)
Conductor MaterialCopper only (individual strands may be tinned or silver-plated; conductor ends must not be soldered)
Tightening Torque4 Nm (35 lb-in)
Recommended Screw DriverPozidriv/Phillips PH2; slotted 1.2 x 8 mm (DIN 5264)
Contact TypeRigid bridging link
Contact MaterialSilver
Connection TypeScrew terminal; if lugs are used, fully insulated lugs or FASTON female terminals must be used; tek vidalı terminallerde saha bağlantısı için Thomas & Betts RE717 pabuç (veya eşdeğeri) kullanılmalı
UL/CSA Rated Insulation Voltage (Ui)600 V AC

Shipping & assurance

For made-to-order products, the procurement and carrier hand-over time is shared with the quotation.

In rare cases, all or part of an order may be unavailable due to stock or procurement updates. In this case, the customer is informed and the relevant product is cancelled and refunded. A product being open for sale does not guarantee that it is in physical store stock.

Delivery and returns